Density Hydrometer, Pesa liquidos

    The  density hydrometer  measures the  density of  light or heavy  liquid        of 20 ° C  /  68 ° F
    at an reference temperature of 4 ° C / 39,2  ° F, water  has its larges density at 4 C !


The formula is :  Density = ro  ,  Weight = m  , Volume = V          ro=   m  
                                                                                                                    V

Nearly every country has a special Hydrometer !


How to use: For using an  hydrometer you require a test jar to make an exact and easy reading!Before and after use clean the hydrometer and test jar with warm water and dry before use. The  hydrometer should also be wiped dry with a linen cloth. After cleaning, the hydrometer should be held only from the thin part above the paper scale. The clean liquid is first poured into the test jar, leaving at least 2” / 5 cm from the rim free. Close the test jar with a clean plastic foil and with the palm of the hand, shake 10 times or stir the liquid well ! Be carefull  if acid or lye is in your  testing liquid ! The  hydrometer is now dipped slowly into the liquid until it floats freely. The hydrometer ha^s to be free of bubbles! Do not let the  hydrometer fall into the test jar! The reading is taken at eye level at the spot where the thin part or stem intersects the liquid, i.e. at the level of the liquid surface. Record the temperature of the liquid. Take care of the temperature of room, liquid and instrument is the same. Store test jar, liquid, instrument about 4 hours in the same room you test!

    Density hydrometers are made for special use in:
    a) Industrial quality used for raw measuring or work measuring.
    b) for official test - scale error 1 division - used for laboratory mea
    suring.
    c) officially tested - instruments with scale error 1 can officially tested - used for highest requirements example: Alcohol, petrol - as tax are to pay on percentage of alcohol and density!


 

Industrial quality:

Density Hydrometer,
Pesa liquidos

1)a. range finder        
range               Catalogue no
                         
+ - 200 mm
0,650-1,000           11.90.
1,000-2,000           11.91.

1)b. range finder        
range               Catalogue no
                          
+ - 300 mm
0,700-1,000           13.20.
1,000-2,000           13.24.

2) range of 200 grad, in0,002      
range               Catalogue no
                                  + - 300 mm
0,600-0,800           12.80.
0,800-1,000           12.81.
1,000-1,200           12.82.
1,200-1,400           12.83.
1,400-1,600           12.84.
1,600-1,800           12.85.
1,800-2,000           12.86.

3) range of 100 grad, in0,001
range               Catalogue no
                         
+ - 300 mm
0,600-0,700           12.60.
0,700-0,800           12.61.
0,800-0,900           12.62.
0,900-1,000           12.63.
1,000-1,100           12.64.
1,100-1,200           12.65.
1,200-1,300           12.66.
1,300-1,400           12.67.
1,400-1,500           12.68.
1,500-1,600           12.69.
1,600-1,700           12.70.
1,700-1,800           12.71.
1,800-1,900           12.72.
1,900-2,000           12.73.
4) 
 

5) range of 150/250
in 0,005
range               Catalogue no
                          + -  180 mm
0,700-0,850           13.00.
0,850-1,000           13.01.
1,000-1,250           13.02.
1,250-1,500           13.03.
1,500-1,750           13.04.
1,750-2,000           13.05.
 

For official test

1. DIN range of 100 - M 100,
length + - 260 mm, in 0,002
range               Catalogue no
0,600-0,700           31.50.
0,700-0,800           31.51.
0,800-0,900           31.52.
0,900-1,000           31.53.
1,000-1,100           31.54.
1,100-1,200           31.55.
1,200-1,300           31.56.
1,300-1,400           31.57.
1,400-1,500           31.58.
1,500-1,600           31.59.
1,600-1,700           31.60.
1,700-1,800           31.61.
1,800-1,900           31.62.
1,900-2,000           31.63.

2. DIN range of 50 - M 50,
length + - 240 mm, in 0,001
range               Catalogue no
0,600-0,650           30.50.
0,650-0,700           30.51.
0,700-0,750           30.52.
0,750-0,800           30.53.
0,800-0,850           30.54.
0,850-0,900           30.55.
0,900-0,950           30.56.
0,950-1,000           30.57.
1,000-1,050           30.58.
1,050-1,100           30.59.
1,100-1,150           30.60.
1,150-1,200           30.61.
1,200-1,250           30.62.
1,250-1,300           30.63.
1,300-1,350           30.64.
1,350-1,400           30.65.
1,400-1,450           30.66.
1,450-1,500           30.67.
1,500-1,550           30.68.
1,550-1,600           30.69.
1,600-1,650           30.70.
1,650-1,700           30.71.
1,700-1,750           30.72.
1,750-1,800           30.73.
1,800-1,850           30.74.
1,850-1,900           30.75.
1,900-1,950           30.76.
1,950-2,000           30.77.

ASTM range of 50, 60/60 F,
length + - 300 mm, in 0,0005
range               Catalogue no
0,600-0,650            03.00.
0,650-0,700            03.01.
0,700-0,750           03.02.
0,750-0,800           03.03.
0,800-0,850           03.04.
0,850-0,900           03.05.
0,900-0,950           03.06..
0,950-1,000           03.07.
1,000-1,050           03.08.
1,050-1,100           03.09